PROBLEM:

On servers with on-board AHCI based SATA controllers, controllers can be set
to pure HBA mode or RAID mode using system BIOS. System BIOS changes the PCI
sub-system IDs based on this mode.

LSI's software RAID driver (megasr) can claim RAID mode AHCI controllers and
provide RAID 0, 1, 10 & 5 functionality. The megasr driver considers all four
PCI IDs to decide if it supports a controller.

The native ahci driver Linux kernel looks at only the vendor & device IDs. It
ignores the subsystem IDs. As a result it ignores the RAID mode. While this
behavior always existed, it poses a problem only in Red Hat Enterprise Linux 5
(RHEL5). All other Red Hat distributions (RHEL3, RHEL4) load the driver from
a driver disk (DUD) if it exists before loading the native drivers from the
installation media. To override native ahci and use megasr, users just had to
use the megasr DUD. Once megasr is loaded, these older versions added megasr
to the initial RAM disk image (initrd) and removed ahci from it.

RHEL5 installation loads native ahci driver even when megasr DUD is present.
It also includes ahci in the initrd. This is an undocumented deviation from
the normal behavior. Red Hat initially set to resolve this in the next RHEL5
update (RHEL 5.1). But later it rejected the issue.

SOLUTION:

1. 	To prevent ahci from loading ahead of megasr, use "noprobe" option at
	the installation kernel boot prompt (in addition to "dd" option). This
	lets you install RHEL5 on megasr virtual drive.

	boot: linux dd noprobe=ata1 noprobe=ata2 noprobe=ata3 noprobe=ata4

2.	At the last step of the installation (after all the packages are
	installed) RHEL5 prompts you to reboot. At this point, the initrd is
	built with ahci driver. Megasr must be added and ahci must be deleted
	from initrd before you reboot.

3.	Pressing Ctrl+Alt+F2 would take you to a text console prompt. Go to 
	the mounted directory run replace_ahci.sh script. This script will
	modify /etc/modprobe.conf and /etc/modprobe.d/blacklist if required.
	It will create a new initrd image.

4.	The replace_ahci.sh script will be provided in RHEL5 DUD floppy image.

5.	If the script is in floppy drive, you have to mount it first. In the 
	normal system, we mount using /dev/sd<x> device names to mount a device. 
	In the pre-installation environment, you may not
	have these names created. You can find the major and minor numbers of
	your device by reading /proc/partitions file. Using those numbers in
	mknod, you can create your own device name.

	Example:
	For RHEL 5.x (till RHEL5.6 follow the below steps):

	Connect USB Floppy Drive
	cat /proc/partitions (It will show where the Floppy is loaded)
	mkdir /abc (abc is a folder)
	mknod /dev/sdx b 8 16 (X= partion)
	mount dev/sdx /abc
	cd /abc
	run the replace_ahci typing the following command
	./replace_ahci.sh

	For RHEL5.7 follow the below steps: 
	Connect USB Floppy Drive
	cat /proc/partitions (It will show where the Floppy is loaded)
	mkdir /abc (abc is a folder)
	mknod  -m   /dev/sdx  b  p  (X= partion)
	mount dev/sdx /abc
	cd /abc
	run the replace_ahci typing the following command
	./replace_ahci.sh


Known Restrictions:
1. 	Following steps to be followed during the OS installation using DUD images
	For SLES (32bit and 64bit) platforms.

	To use AHCI controller in LSI Raid Mode
	- AHCI controller has to be in LSI RAID mode.
	- brokenmodules=ahci has to be provided during OS installation.

	To use SCU controller in LSI Raid Mode
	- SCU controller has to be in LSI RAID mode.
	- brokenmodules=isci  has to be provided during OS installation.

	To use both controllers in LSI Raid Mode
	- brokenmodules=ahci,isci  has to be provided during OS installation.

2.      Following steps to be followed during the OS installation using DUD images
        For all SLES platforms (32bit and 64bit).
        Example:
        For SLES-11 SP1 (32bit and 64bit) platforms, as the dud image size exceedes floppy
        disk size.

        a. copy the image file to any linux system.
           megasr-14.00.0722.2010-1-sles11-sp1-x86_64.img for 64bit SLES11 SP1
           megasr-14.00.0722.2010-1-sles11-sp1-x86.img for 32bit SLES11 SP1

        b. Create a directory ex: "mkdir image"

        c. Mount the dud image on to image directory using the below command.
           "mount -oloop megasr-14.00.0722.2010-1-sles11-sp1-<arch>.img image"

        d. Change the directory to image ("cd image").
           Copy the contents of the image directory into USB drive.
           (Contents of the image starts with 01 directory, copy the 01 directory to USB Drive)

        e. Use this USB drive to provide the third-party driver during the OS instalaltion.

        f. Enter following command while giving driver "brokenmodules=ahci,isci".

        g. Make sure that USB drive is formatted before using for OS installation using DUD images.

3.	For RHEL-6.1 GA and RHEL-6.2 GA (32bit and 64bit) platform OS installation using 
	the SWR DUD images.
        Follow the below mentioned steps.
	While booting from DVD press esc key to give 3rd party driver using the following commands 

	To use AHCI controller in LSI Raid Mode
	- Provide the command "Linux dd blacklist=ahci nodmraid"

	To use SCU controller in LSI Raid Mode
	- Provide the command "Linux dd blacklist=isci nodmraid"

	To use both controllers in LSI Raid Mode
	- Provide the command "Linux dd blacklist=ahci,isci nodmraid"

	If OS installation is on SCU and if LSI don't support AHCI controller for the same machine 
	don't use blacklist=ahci. If a CD/DVD-ROM is connected to AHCI port installation will fail.

4.	For RHEL-5.7 GA and RHEL-5.8 GA (32bit and 64bit) platform OS installation using the SWR DUD images.
        Follow the below mentioned steps.
	While booting from DVD press esc key to give 3rd party driver using the following commands 

	To use AHCI controller in LSI Raid Mode
	- Provide the command "Linux dd blacklist=ahci"

	To use SCU controller in LSI Raid Mode
	- Provide the command "Linux dd blacklist=isci"

	To use both controllers in LSI Raid Mode
	- Provide the command "Linux dd blacklist=ahci,isci"

	If OS installation is on SCU and if LSI don't support AHCI controller for the same machine 
	don't use blacklist=ahci. If a CD/DVD-ROM is connected to AHCI port installation will fail.

5.      Upgrading MegaSR driver.

	Following steps to be followed during the megasr driver upgrade if the OS installation is done on megasr Virtual Drive, using megasr dud images.

        For all RHEL6.x platforms (32bit and 64bit)
	 -------------------------------------------
        Example:
        
        a. copy the dud image file to target linux system.
           megasr-15.00.0315.2012-1-rhel6x-ga-x86.img for 32bit RHEL6.x
           megasr-15.00.0315.2012-1-rhel6x-ga-x86_64.img for 64bit RHEL6.x

        b. Create a directory ex: "mkdir image"

        c. Mount the dud image on to image directory using the below command.
           "mount -oloop megasr-15.00.0315.2012-1-rhel6x-ga-<arch>.img image"

        d. Change the directory to image ("cd image").
                32bit: (32bit dud image must be mounted)
                cd image/rpms/i386/
		install (upgrade) the kmod rpm with --force option.
		Rpm -Uvh kmod-megasr-2.2.3.rhtest60s10-1.el6.i686.rpm --force
                
		64bit: (64bit dud image must be mounted)
                cd image/rpms/x86_64/
                install (upgrade) the kmod rpm with --force option.
		Rpm -Uvh kmod-megasr-2.2.3.rhtest60s10-1.el6.x86_64.rpm --force

       e. Reboot the system to verify that the driver has been updated.

	For SLES 11 (32bit and 64bit)
	-----------------------------
        a. copy the dud image file to target linux system.
           megasr-15.00.0329.2012-1-sles11-sp2-x86_64.img for 32bit RHEL6.x

        b. Create a directory ex: "mkdir image"

        c. Mount the dud image on to image directory using the below command.
           "mount -oloop megasr-15.00.0329.2012-1-sles11-sp2-x86_64.img image"

        d. Change the directory to image ("cd image").
		cd image/01/linux/suse/x86_64-sles11/install/
		upgrade the rpm with --force option.
		rpm -Uvh lsi-megasr-kmp-15.00.0329.2012-1_3.0.13-0.27.x86_64.rpm .force 

       e. Reboot the system to verify that the driver has been updated.


	For all RHEL 5.x platforms (32 bit and 64 bit)
	----------------------------------------------

	a. The SWR5 driver update package utilizes the DKMS package which can be found at the following link (can be subject to change):
		http://linux.dell.com/dkms/

	b. Download the Latest stable RPM. The format will be: 
		dkms-x.x.xx.x-x.noarch.rpm
 
	c. Save it in a folder on the system, then open up a Terminal window and navigate to the folder.
 
	d. Install the dkms rpm first using the following command:
		rpm -ivh dkms-x.x.xx.x-x.noarch.rpm

	e. Install the megasr-dkms rpm using the following command:
		rpm -ivh megasr-x.x.xx.x-x.noarch.rpm

        f. Reboot the system to verify that the driver has been updated.
	
	NOTE : "rpm -ivh megsr-x.x.x.x.noarch.rpm" option needs to be used if driver is upgraded for the first time.
	From next time onwards use "rpm -Uvh megsr-x.x.x.x.noarch.rpm" command.

6.	The use of a 32-bit hypervisor as a virtualization host is deprecated on SLES11-SP1.
	The following link provides more information.
	http://www.suse.com/releasenotes/x86_64/SUSE-SLES/11-SP1/#rnotes-deprecated.

7.	"Native video driver in SLES and RHEL does not support S1-sleep/Standby mode. 
	Due to this, Standby mode will work only with specific external graphics cards."	